Electric Vehicle charger testing tool, essential for the installer and maintainer. Guarantees correct operation of any charger with both hose and base TYPE 2 connector.
Power supply
4 alkaline batteries LR06/AA 1,5 V
Connection
Plug suitable to socket outlet or connector Type 2 according to EN 62196-2
External charging socket to generate actual consumption
Máx. 8 A (1800 W)
Vehicle state (CP) simulation
A-Vehicle not connected / B-Vehicle connected not charging / C-Vehicle connected and charging / D-Vehicle connected and charging with ventilation
Vehicle malfunction generation
CP to ground malfunction/CP D diode malfunction
Cable coding (PP) simulation
Open / 13 A / 20 A / 32 A / 64 A
Residual AC current test
30 mA (RCD)
DC leakage current test
6 mA (RDC-DD)
Material
ABS, decor seal TPE
Degree of protection
IP40 according to EN 60529
Connection cable length
1 m
Operating temperature
0 ºC to 40 ºC
Documentation and downloads
General Information: +34 91 567 22 77
Email: info@orbis.es
Technical Service: +34 91 970 10 26
Technical Service Email: servicio.tecnico@orbis.es
Mon-Thu, 7:00 a 15:30 | Fri, 7:00 a 14:00